Job Aid: Replacing the Remote Supervisor Adapter (RSA)
Figure 51: RSA faceplate and connectors
Figure notes:
1. Power retaining clip
2. External power supply connector
3. Power and error LEDs
!
CAUTION:
Wear an antistatic wrist ground strap whenever handling the server or server
CAUTION:
components. Connect the strap to an approved ground, such as an unpainted
metal surface.
Backing up the RSA
Note:
When replacing the RSA in an S8500 server functioning as the Secure Services
Note:
Gateway (SSG) for a Secure Access and Control (SAC) deployment, back up the
SSG configuration. For information on how to backup the SSG configuration, see
Secure Services Gateway (SSG) Maintenance Guide, 19-300174. Backing up
the server is not applicable for the SSG.
Backup the RSA configuration before shutting down the S8500 server. If it is not possible to
backup the RSA at this time, locate the most recent RSA backup file before proceeding.
Complete the following steps to backup the RSA configuration:
1. Establish a connection from the services laptop to the RSA:
Direct connect through a crossover cable from the laptop to the Ethernet port on the RSA
l
Other network connection
l
2. Open a internet browser window.
3. In the address field of the browser, type the IP address for the RSA and press Enter.
The Enter Network Password window appears
170 Job Aids for Field Replacements (FRUs) for the Avaya S8500 Server
1
2
3
4
4. ASM RS-485 connector
5. RS-232 serial connector
6. Ethernet connector
5
6
h3msrsap LAO 071503
(Figure
52).