Viewing the Test Log

Errors reported by the diagnostic test are displayed by the program as a failed test.
To view details of a failure or to view a list of test results, do the following from any
test category panel:
SIMM/DIMM Memory Errors
SIMM/DIMM error messages issued by the IBM PC Enhanced Diagnostics:
4-8
3745-XXA 4-8 3746-9X0: 6578 SPIM
Press F3 to activate the log file.
Press F3 again to save the file to diskette or F2 to print the file.
Message
Failure Found
2xx-1y
A memory error was detected in
SIMM socket y.
2xx-2y
A memory error was detected in
DIMM socket y.
Corrupt
Information in BIOS is not as
BIOS
expected.
Not able to find expected DMI
information from BIOS.
Memory controller chipset vendor
ID does not match expected
value.
Test
User stopped test.
aborted by
user
Note:
In the code y is the SIMM/DIMM socket number. See "System Board Layout" on
page H-5 to locate memory socket.
Recommended Actions
Replace the SIMM in the socket
identified by the last digit of the
error code.
Rerun the test.
If the same error code occurs
again, replace the system board.
Replace the DIMM in the socket
identified by the last digit of the
error code.
Rerun the test.
If the same error code occurs
again, replace the system board
or where memory is on the
processor card, replace the
processor card.
Reflash the BIOS.
Replace the system board.
Restart test.