4-22
3745-XXA 4-22 3746-9X0: 6578 SPIM
Diagnostic Error Code
080-197-XXX
Game Port interface test warning
080-198-XXX
Game Port interface test aborted
080-199-XXX
Game Port interface test failed, cause
unknown
086-000-XXX
Mouse Port interface Test Passed
086-001-XXX
Mouse Port interface Presence
086-032-XXX
Mouse Port interface Device controller
failure
086-035-XXX
Mouse Port interface Reset
086-040-XXX
Mouse Port interface IRQ failure
086-195-XXX
Mouse Port interface Test aborted by user
086-196-XXX
Mouse Port interface test halt, error
threshold exceeded
086-197-XXX
Mouse Port interface test warning
086-198-XXX
Mouse Port interface test aborted
FRU to replace/action to take
1. Make sure that the component that
is called out is enabled or
connected.
2. Rerun the test.
3. Component that is called out in
warning statement
4. Component under test
1. If a component is called out, make
sure that it is enabled or
connected.
2. Flash the system and retest.
3. Go to "Undetermined Problems" on
page 3-22.
1. Go to "Undetermined Problems" on
page 3-22.
2. Flash the system and retest.
3. Replace component under function
test.
No action
1. Mouse
2. System board
1. Mouse
2. System board
1. Mouse
2. System board
1. Run Setup.
2. Mouse
3. System board
1. Information
2. Restart the test, if you need to.
1. Press F3 to review the log file. See
"Viewing the Test Log" on
page 4-8.
2. Restart the test to reset the log file.
1. Make sure that the component that
is called out is enabled or
connected.
2. Rerun the test.
3. Component that is called out in
warning statement
4. Component under test
1. If a component is called out, make
sure that it is enabled or
connected.
2. Flash the system and retest.
3. Go to "Undetermined Problems" on
page 3-22.

Advertisement