Table 3-1 (Page 8 of 12). POST Errors
Symptom / Error
10101, 10102, 10104
10105, 10106, 10107
10108, 10109, 10111
10112, 10113, 10114
10115, 10116
10103, 10110, 101171
10117
Not listed previously.
10118
10119
10120
10132, 10133, 10134
10135, 10136, 10137
10138, 10139, 10140
10141, 10142, 10143
10144, 10145, 10146
10147, 10148, 10149
10150, 10151, 10152
10153
101XX
Not listed previously.
10450, 10451, 10490
10491, 10492, 10499
Read/write error.
10452
Seek test error.
10453
Wrong drive type?
10454
Sector buffer test error.
10455, 10456
Controller error.
10459
Drive diagnostic command error.
10461
Drive format error.
FRU to replace / Action to take
1. Have customer verify correct
operating system device drivers are
installed and operational.
2. Modem
1. System Board
2. Data/Fax Modem
1. Check system speaker.
2. Check PSTN cable.
3. External DAA (if installed)
4. Modem
1. Run Diagnostics and verify the
correct operation of the modem slot.
2. Modem
1. Diagnostics detected a non-IBM
modem.
2. Modem
1. Check PSTN Cable.
2. External DAA (if installed)
3. Modem
Modem
1. Data/Fax Modem
2. System Board
1. Modem Adapter/A
2. Data/Fax Modem
3. System Board
1. Run Enhanced Diagnostics.
2. Hard Disk Drive
3. System Board
Run Enhanced Diagnostics.
Information only
Run Enhanced Diagnostics.
Run Enhanced Diagnostics.
Information only
Run Enhanced Diagnostics.
Chapter 3. Service Processor Troubleshooting