4-10
3745-XXA 4-10 3746-9X0: 6578 SPIM
Diagnostic Error Code
000-197-XXX
BIOS test warning
000-198-XXX
BIOS test aborted
000-199-XXX
BIOS test failed, cause unknown
000-250-XXX
BIOS APM failure
000-270-XXX
BIOS ACPI failure
001-000-XXX
System Test Passed
001-00X-XXX
System Error
001-01X-XXX
System Error
001-024-XXX
System Addressing test failure
001-025-XXX
System Checksum Value error
001-026-XXX
System FLASH data error
001-027-XXX
System Configuration/Setup error
001-032-XXX
System Device Controller failure
001-034-XXX
System Device Buffer Allocation failure
001-035-XXX
System Device Reset condition detected
001-036-XXX
System Register error
001-038-XXX
System Extension failure
FRU to replace/action to take
1. Make sure that the component that
is called out is enabled or
connected.
2. Rerun the test.
3. Component that is called out in
warning statement
4. Component under test
1. If a component is called out, make
sure that it is enabled or
connected.
2. Flash the system and retest.
3. Go to "Undetermined Problems" on
page 3-22.
1. Go to "Undetermined Problems" on
page 3-22.
2. Flash the system and retest.
3. Replace component under function
test.
1. Flash the system.
2. System board
1. Flash the system.
2. System board
No action
System board
System board
System board
1. Flash the system.
2. System board
1. Flash the system.
2. System board
1. Run Setup.
2. Flash the system.
3. System board
System board
1. Reboot the system.
2. Flash the system.
3. Run memory test.
4. System board
System board
System board
1. Adapter card
2. System board