Tightening torques:
1. Firstly, only tighten the nuts by hand.
Tightening torque: 0.5 Nm
2. Then tighten the nuts in the specified sequence 1 to 4.
Tightening torque: 6 Nm
Special points to note in relation to mounting on a cold plate
To improve heat transfer, a heat-conducting medium must be used. Special spherical-
indented heat-conducting foil must be used for this purpose. Every Motor Module Booksize
Compact is supplied with heat-conducting foil cut to the right size. Note the mounting
position of the heat-conducting foil.
Note
• Also replace the heat-conducting foil when replacing a component.
• Only use heat-conducting foil released or supplied by Siemens.
Heat-conducting foil, 50 mm
Heat-conducting foil, 75 mm
7.8

Technical data

7.8.1

Single Motor Modules

Table 7- 9
Technical data Single Motor Modules Booksize Compact (3 A to 18 A)
Motor Modules Booksize Compact
Output current
Rated current (l
)
n
Base-load current (I
)
H
Intermittent duty current (I
Peak current (l
)
max
Output voltage
DC link current I
d rated
DC-link voltage
(up to 2000 m above sea level)
DC-link capacitance
Overvoltage trip
Undervoltage trip
1)
Electronics power supply
Booksize Power Units
Manual, (GH2), 07/2016, 6SL3097-4AC00-0BP8
6SL3420–
A
AC
A
) 40 %
A
S6
AC
A
AC
V
AC
A
DC
V
DC
μF
V
DC
V
DC
V
DC
Motor Modules Booksize Compact
Article No.
6SL3162-6FB01-0AA0
6SL3162-6FC01-0AA0
1TE13-0AA.
1TE15-0AA.
3
5
2.6
4.3
3.5
6
9
15
0 ... 0.717 x DC-link voltage
3.6
6
110
110
24 (20.4 ... 28.8)
7.8 Technical data
1TE21–0AA.
1TE21–8AA.
9
18
7.7
15.3
10
24
27
54
11
22
510 ... 720
110
235
820 ± 2 %
380 ± 2 %
477

Hide quick links: