6.4.8

Technical data for Motor Modules Booksize with 300% overload

6.4.8.1

Single Motor Modules (300% overload)

Table 6- 45
Technical data Single Motor Modules (3 to 18 A) with 300% overload
Cold plate
Output current
Rated current (I
)
n
Base-load current (I
)
H
Intermittent duty current (I
Peak current (I
)
max
Output voltage
DC link current I
d rated
DC-link voltage
(up to 2000 m above sea level)
DC-link capacitance
Overvoltage trip
Undervoltage trip
1)
Electronics power supply
Electronics current drawn
at 24 VDC
Current carrying capacity
DC-link busbars
Reinforced DC-link busbars
24 VDC busbars
Unit rating
2)
Based on I
(600 VDC; 4 kHz)
n
Based on I
H
Total power loss
(including electronics losses, see Power
loss tables (Page 756))
Max. pulse frequency
without derating
with derating
Output frequency
Max. permissible heat sink temperature
Ventilation clearances
above/below
Weight
Default for 400 V line systems; undervoltage trip threshold can be reduced by up to 80 V and is adjusted to the parame-
1)
terized rated voltage
Rated power of a typical standard induction motor at 400 V 3 AC
2)
Booksize Power Units
Manual, (GH2), 07/2016, 6SL3097-4AC00-0BP8
6SL3126-
A
AC
A
) 40%
A
S6
AC
A
AC
V
AC
A
DC
V
DC
μF
V
DC
V
DC
V
DC
A
DC
A
DC
A
DC
A
DC
kW
kW
W
kHz
kHz
Hz
° C
mm
kg
1TE13-0AA4
1TE15-0AA4
3
5
2.6
4.3
3.5
6
9
15
0 ... 0.717 x DC-link voltage
3.6
6
110
110
24 (20.4 ... 28.8)
1.6
2.7
1.1
2.3
45.5
70.6
70
70
4.2
4.2
Motor Modules Booksize
6.4 Motor Modules with cold plate
1TE21-0AA4
1TE21-8AA4
9
7.7
10
27
11
510 ... 720
110
820 ± 2 %
380 ± 2 %
0.65
100
150
20
4.8
4.1
95.6
4
16
0 ... 550
70
≥ 80
4.5
18
15.3
24
54
22
220
9.7
8.2
180.6
70
4.5
439