Cabinet design and EMC Booksize
12.7 Connection systems
Removing the motor connector
1. First loosen the clamp.
2. Simultaneously press the tabs A and B on both sides of the connector using a
screwdriver.
3. Keep both tags pressed and lift the interlock mechanism e.g. using a screwdriver.
4. Remove the Insert and withdraw the motor cable out of the connector.
Figure 12-35 Removing the motor connector, crimped version