12.12 Power losses of the components
12.12.5

Power loss for power units with external air cooling

Table 12- 37
Overview of power loss at rated operation for power units with external air cooling (including electronics
losses)
Active Line Modules
16 kW
36 kW
55 kW
80 kW
120 kW
Smart Line Modules
5 kW
10 kW
16 kW
36 kW
55 kW
Single Motor Modules
3 A
5 A
9 A
18 A
30 A
45 A
60 A
85 A
132 A
200 A
Double Motor Modules
3 A
5 A
9 A
18 A
Power loss of the power electronics + power loss of the 24 V electronics
1)
760
Unit
Internal
Power loss
W
82.8 (60 + 22.8)
W
171 (135 + 36.0)
W
245.6 (200 + 45.6)
W
338.6 (305 + 33.6)
W
533.2 (490 + 43.2)
W
41.2 (22 + 19.2)
W
66.6 (45 + 21.6)
W
64.8 (42 + 22.8)
W
116 (80 + 36)
W
185.6 (140 + 45.6)
W
35.4 (15 + 20.4)
W
43.4 (23 + 20.4)
W
55.4 (35 + 20.4)
W
95.4 (75 + 20.4)
W
99.2 (80 + 19.2)
W
135.2 (110 + 25.2)
W
160.2 (135 + 25.2)
W
196 (160 + 36.0)
W
270.4 (250 + 20.4)
W
455.4 (435 + 20.4)
W
62.6 (35 + 27.6)
W
72.6 (45 + 27.6)
W
92.6 (65 + 27.6)
W
111.2 (80 + 31.2)
External power loss
1)
200
495
700
1045
1710
38
75
123
290
480
15
30
45
90
210
320
455
590
1000
1615
35
60
95
240
Manual, (GH2), 07/2016, 6SL3097-4AC00-0BP8
Total power loss
282.8
666
945.6
1383.6
2243.2
79.2
141.6
187.8
406
665.6
50.4
73.4
100.4
185.4
309.2
455.2
615.2
786
1270.4
2070.4
97.6
132.6
187.6
351.2
Booksize Power Units