Technical Data - Siemens SINAMICS S120 Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Motor-side power components
10.2 Voltage Protection Module VPM
10.2.8

Technical data

Table 10- 15 Technical data
Article No.
Type of voltage
Ramp-up time for VPM
Normal range of the
DC link voltage:
- lower limit
- upper limit
Operating range for VPM
Motor EMF
Clock frequency
Rated current
Time range
0 ... 10 ms
10 ... 500 ms
500 ms ... 2 min
> 2 min
Max. perm. short-circuit time
Safe electrical separation
Permitted humidity
Humidity classification accord-
ing to
EN 60721-3-3
Permissible ambient tempera-
ture
Cooling method
Weight
Dimensions (H x W x D) [mm]
590
VPM 120
6SN1113-1AA00-1JA.
3-phase pulsed AC voltage, motor EMF
120 A
rms
Maximum permissible short-circuit current
1500 A
255 A
90 A
0 A
Between the signal contact and motor cables U, V, W, UL 508 C
Cl. 3K5, condensation and icing excluded
Approx. 6 kg
300 x 150 x 180
VPM 200
6SN1113-1AA00-1KA.
1 s (from pulse enable)
490 V DC
795 V DC
830 ... 2000 V (peak value)
< 1.4 kV
rms
3.2 ... 8 kHz
120 s
< 90 %
Low air temperature 0 °C
0 ... 55 °C
Air-cooled, free convection
Approx. 11 kg
300 x 250 x 190
Manual, (GH2), 07/2016, 6SL3097-4AC00-0BP8
VPM 200 Dynamic
6SN1113-1AA00-1KC.
200 A
rms
2000 A
600 A
200 A
0 A
Approx. 13 kg
300 x 250 x 260
Booksize Power Units

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents