Huawei UPS5000-A-300K-STT User Manual page 232

200 kva-800 kva
Hide thumbs Also See for UPS5000-A-300K-STT:
Table of Contents

Advertisement

UPS5000-A-(200 kVA-800 kVA)
User Manual
Figure 4-4 Running 2
Table 4-3 AC output
Item
Phase voltage (V)
Line voltage (V)
Phase current (A)
Frequency (Hz)
Power factor
Table 4-4 UPS load
Item
Active power (kW)
Apparent power (kVA)
Reactive power (kvar)
Load ratio (%)
Crest factor
Issue 03 (2019-02-15)
On the System Info > Settings > iBOX Settings > Basic Param. screen, if the Number of iBOXs is
not 0 the Battery Detailed Data is displayed on the Runn Info screen.
Copyright © Huawei Technologies Co., Ltd.
Description
AC output phase voltage
AC output line voltage
AC output phase current
AC output frequency
Proportion of output active power to output apparent
power.
Description
Output active power of each phase on the UPS.
Output apparent power of each phase on the UPS.
Output reactive power of each phase on the UPS, that is,
square root of the difference between the square of output
apparent power and the square of output active power.
Load ratio of each phase on the UPS, that is, proportion
of actual power to rated power.
Proportion of the peak value of load current to the valid
value.