• No: Go to step 2.
• Yes: Shut down all failing servers that are related to the cluster. Go to step 2.
Step 2.
Complete the following steps:
a.
Check the power supply LEDs (see "Power-supply LEDs" on page 73).
b.
Turn off the server and all external devices.
c.
Check all internal and external devices for compatibility at
serverproven/
d.
Check all cables and power cords.
e.
Set all display controls to the middle positions.
f.
Turn on all external devices.
g.
Turn on the server. If the server does not start, see "Troubleshooting by symptom" on page 82.
h.
Check the system-error LED on the operator information panel. If it is lit, check the LCD
system information display panel (if available, see "LCD system information display panel" on
page 21).
i.
Check for the following results:
• Successful completion of POST (see "POST" on page 79 for more information)
• Successful completion of startup, which is indicated by a readable display of the operating-
system desktop
Step 3.
Is there a readable image on the monitor screen?
• No: Find the failure symptom in "Troubleshooting by symptom" on page 82; if necessary, see
"Solving undetermined problems" on page 109.
• Yes: Run DSA (see "Running the DSA Preboot diagnostic programs" on page 80).
– If DSA reports an error, follow the instructions in Appendix C "DSA diagnostic test results" on
page 1077.
– If DSA does not report an error but you still suspect a problem, see "Solving undetermined
problems" on page 109.

Diagnostic tools

The section introduces available tools to help you diagnose and solve hardware-related problems.
• LCD system information display panel (available on some models)
Use LCD system information display panel to diagnose system errors quickly.
• Event logs
The event logs list the error codes and messages that are generated when an error is detected for the
subsystems IMM2, POST, DSA, and the server baseboard management controller. See "Event logs" on
page 77 for more information.
• Integrated management module II (IMM2)
The IMM2 combines service processor functions, video controller, and remote presence and blue-screen
capture features in a single chip. The IMM provides advanced service-processor control, monitoring, and
alerting function. If an environmental condition exceeds a threshold or if a system component fails, the
IMM lights LEDs to help you diagnose the problem, records the error in the IMM event log, and alerts you
to the problem. Optionally, the IMM also provides a virtual presence capability for remote server
management capabilities. The IMM provides remote server management through the following industry-
standard interfaces:
.