Lenovo System x3650 M5 Installation And Service Manual page 526

Hide thumbs Also See for System x3650 M5:
Table of Contents

Advertisement

Prefix: PLAT ID: 0810
User Response
1. Make sure that the connectors on fan n are not damaged.
2. Make sure that the fan n connectors on the system board are not damaged.
3. Make sure that the fans are correctly installed.
4. Reseat the fans.
5. Replace the fans. (n = fan number)
• 800b050a-1e83ffff : Non-redundant:Insufficient Resources for [RedundancySetElementName] has
asserted. (Fan Zone 3)
This message is for the use case when a Redundancy Set has transitioned to Non-redundant:Insufficient
Resources.
May also be shown as 800b050a1e83ffff or 0x800b050a1e83ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Fan Failure
SNMP Trap ID
11
CIM Information
Prefix: PLAT ID: 0810
User Response
1. Make sure that the connectors on fan n are not damaged.
2. Make sure that the fan n connectors on the system board are not damaged.
3. Make sure that the fans are correctly installed.
4. Reseat the fans.
5. Replace the fans. (n = fan number)
• 800b050a-1e84ffff : Non-redundant:Insufficient Resources for [RedundancySetElementName] has
asserted. (Fan Zone 4)
This message is for the use case when a Redundancy Set has transitioned to Non-redundant:Insufficient
Resources.
May also be shown as 800b050a1e84ffff or 0x800b050a1e84ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
514
Lenovo System x3650 M5 Installation and Service Guide