May also be shown as 800102041d06ffff or 0x800102041d06ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Fan Failure
SNMP Trap ID
11
CIM Information
Prefix: PLAT ID: 0480
User Response
1. Reseat the failing fan n, which is indicated by a lit LED near the fan connector on the system
board.
2. Replace the failing fan. (n = fan number)
Fan 6B Tach :
• 80010204-1d07ffff : Numeric sensor [NumericSensorElementName] going low (lower critical) has
asserted. (Fan Riser1A Tach)
This message is for the use case when an implementation has detected a Lower Critical sensor going low
has asserted.
May also be shown as 800102041d07ffff or 0x800102041d07ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Fan Failure
SNMP Trap ID
11
CIM Information
Prefix: PLAT ID: 0480
User Response
1. Reseat rear hdd cage riser n.
2. Remove the following component and identify the problem. a. HDD drive b. HDD cable c. RAID
card d. cage riser n
3. Replace rear hdd cage riser n (n = riser number).
• 80010204-1d08ffff : Numeric sensor [NumericSensorElementName] going low (lower critical) has
asserted. (Fan Riser1B Tach)
Appendix A. Integrated management module II (IMM2) error messages
445