Lenovo System x3650 M5 Installation And Service Manual page 520

Hide thumbs Also See for System x3650 M5:
Table of Contents

Advertisement

Automatically notify support
No
Alert Category
Warning - Redundant Power Supply
SNMP Trap ID
10
CIM Information
Prefix: PLAT ID: 0561
User Response
No action; information only.
• 800b0108-1301ffff : Redundancy Lost for [RedundancySetElementName] has asserted. (Power
Unit)
This message is for the use case when Redundancy Lost has asserted.
May also be shown as 800b01081301ffff or 0x800b01081301ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Redundant Power Supply
SNMP Trap ID
9
CIM Information
Prefix: PLAT ID: 0802
User Response
1. Check the LEDs for both power supplies.
2. Follow the actions in Power-supply LEDs.
• 800b010a-1e81ffff : Redundancy Lost for [RedundancySetElementName] has asserted. (Fan Zone
1)
This message is for the use case when Redundancy Lost has asserted.
May also be shown as 800b010a1e81ffff or 0x800b010a1e81ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Fan Failure
508