This message is for the use case when an implementation has detected a Drive has been Added.
May also be shown as 806f000d042fffff or 0x806f000d042fffff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0162
User Response
No action; information only.
• 806f000f-220101ff : The System [ComputerSystemElementName] has detected no memory in the
system. (ABR Status)
This message is for the use case when an implementation has detected that memory was detected in the
system.
May also be shown as 806f000f220101ff or 0x806f000f220101ff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0794
User Response
1. Make sure that one or more DIMMs are installed in the server, and resolve any other currently
existing memory errors.
2. If no memory fault is recorded in the logs and no DIMM connector error LEDs are lit, verify that
all DIMM connectors are enabled using the Setup utility or the ToolsCenter Suite CLI.
3. Re-Install all DIMMs verifying the correct population sequence, according to the service
information for this product.
4. Replace DIMMs.
5. Recover the server firmware from the backup page: a. Restart the server. b. At the prompt, press
F3 to recover the firmware. c. Update the server firmware on the primary page. Important: Some