Lenovo System x3650 M5 Installation And Service Manual page 459

Hide thumbs Also See for System x3650 M5:
Table of Contents

Advertisement

• 80010204-1d0affff : Numeric sensor [NumericSensorElementName] going low (lower critical) has
asserted. (Fan Riser2B Tach)
This message is for the use case when an implementation has detected a Lower Critical sensor going low
has asserted.
May also be shown as 800102041d0affff or 0x800102041d0affff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Fan Failure
SNMP Trap ID
11
CIM Information
Prefix: PLAT ID: 0480
User Response
1. Reseat rear hdd cage riser n.
2. Remove the following component and identify the problem. a. HDD drive b. HDD cable c. RAID
card d. cage riser n
3. Replace rear hdd cage riser n (n = riser number).
• 80010701-0701ffff : Numeric sensor [NumericSensorElementName] going high (upper non-critical)
has asserted. (RS1 RR Amb Temp)
This message is for the use case when an implementation has detected an Upper Non-critical sensor
going high has asserted.
May also be shown as 800107010701ffff or 0x800107010701ffff
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - Temperature
SNMP Trap ID
12
CIM Information
Prefix: PLAT ID: 0490
User Response
Appendix A. Integrated management module II (IMM2) error messages
447

Advertisement