About The Technical Reference Manual - ABB Relion 670 Series Technical Reference Manual

Busbar protection
Hide thumbs Also See for Relion 670 Series:
Table of Contents

Advertisement

Section 1
Introduction
1.1.2
22
manual should be used as a technical reference during the engineering phase,
installation and commissioning phase, and during normal service.
The Installation and Commissioning Manual (ICM) contains instructions on
how to install and commission the protection IED. The manual can also be used as
a reference during periodic testing. The manual covers procedures for mechanical
and electrical installation, energizing and checking of external circuitry, setting and
configuration as well as verifying settings and performing directional tests. The
chapters are organized in the chronological order (indicated by chapter/section
numbers) in which the protection IED should be installed and commissioned.
The Operator's Manual (OM) contains instructions on how to operate the
protection IED during normal service once it has been commissioned. The
operator's manual can be used to find out how to handle disturbances or how to
view calculated and measured network data in order to determine the cause of a fault.
The Engineering Manual (EM) contains instructions on how to engineer the IEDs
using the different tools in PCM600. The manual provides instructions on how to
set up a PCM600 project and insert IEDs to the project structure. The manual also
recommends a sequence for engineering of protection and control functions, LHMI
functions as well as communication engineering for IEC 61850 and DNP3.

About the technical reference manual

The following chapters are included in the technical reference manual.
Local HMI describes the control panel on the IED and explains display
characteristics, control keys and various local HMI features.
Basic IED functions presents functions for all protection types that are
included in all IEDs, for example, time synchronization, self supervision with
event list, test mode and other general functions.
Current protection describes functions, for example, over current protection,
breaker failure protection and pole discordance.
Voltage protection describes functions for under voltage and over voltage
protection and residual over voltage protection.
Frequency protection describes functions for over frequency, under frequency
and rate of change of frequency protection.
Multipurpose protection describes the general protection function for current
and voltage.
Control describes control functions, for example, synchronization and
energizing check and other product specific functions.
Logic describes trip logic and related functions.
Monitoring describes measurement related functions that are used to provide
data regarding relevant quantities, events and faults, for example.
Metering describes pulse counter logic.
Station communication describes Ethernet based communication in general,
including the use of IEC 61850 and horizontal communication via GOOSE.
Remote communication describes binary and analog signal transfer, and the
associated hardware.
Hardware describes the IED and its components.
1MRK 505 208-UEN B
Technical reference manual

Hide quick links: