4.14.1 Setup

Radar type
Transmission
(TR unit)
output
FAR-2x17
12 kW
(RTR-078)
FAR-2x27
25 kW
(RTR-079)
FAR-2x37S
30 kW
(RTR-080)
FAR-2827W
25 kW
(RTR-081)
FAR-2837SW
30 kW
(RTR-082)
* As for the measurements, perform on the TB board: HV J651 and J482 on the HV-9017 board. Refer
to the previous page.
VR1: Output voltage adjustment
Between TP1 and TP2
34.7 to 35.3 VDC
JP1
COM      300 V
500 V
Type
JP1
JP2
A
300 V
330 V
B
500 V
330 V
C
300 V
260 V
D
300 V
300 V
E
500 V
300 V
4.14 Change of Transmission HV setting: HV-9017
RPU-013
SER. NO. Type
4317-xxxx
A
COM-300V COM-330V
4318-xxxx
B
COM-500V COM-330V
TP1 to TP4
J482: HV output
A/B type marking
Fig. 4.14.3 HV-9017 Board
4-70
Table 4.14.1 Setting of HV-9017
HV-9017
Jumper setting
JP1
JP2
JP2
COM      300 V
Adjustment Specification*
310 to 350 V
Adjustment
of Main
Inverter
Adjustments on
the VR1 so that
520 to 580 V
34.7-35.3 VDC
is achieved
between
TP1 and TP2.
330 V

Advertisement