7.2.7 Turning operation

1. Automatic tuning operation
The automatic tuning operation includes full search and small search. In these automatic
tuning operations, a start command sent from the SPU board is executed on the RFC
board to control tuning voltage of the MIC. After searching is complete, tracking
operation starts to find the maximum tuning point at all times. Changing tuning voltage
changes local frequency in the MIC. The maximum point of tuning is where the output
frequency of the MIC is converted to the IF frequency of 60 MHz.
A start command, manual setting values, tuning indicator signal (TUNE IND), and MIC
monitor signal (D-MONI signal) presented in a self-test are sent and received using
serial data between the SPU board and RFC board.
Fig. 7.2.17 Schematic Diagram of TUNE Control
The tuning value obtained in full search and small search is saved at U27 (SRAM) of
the RFC board. Searching is performed based on TUNE IND signals.
32V
5V
5V
3V
1V
LP
LP
TUNE Initialize
Tracking
M3
M2
M1
S2
S1
Pulse wide
Fig. 7.2.18 TUNE Control
Tracking
Small
stop
search
Tracking
ST-BY
7-23
7.2 Antenna Unit
Small
search
Tracking
Tx
Changing
Pulse wide
Time
Time