Alarm Output Setting - Furuno FAR-2107 Series Service Manual

Marine radar/arpa
Hide thumbs Also See for FAR-2107 Series:
Table of Contents

Advertisement

4.11 Alarm Output Setting

4.11.1 SYSTEM FAIL alarm output setting
When the processor unit RPU-013 fails, SYSTEM FAIL ALARM detected by the control
unit is outputted from EXT ALARM terminal J612-#11/12 of RPU-013. The setting for
alarm output is executed as shown below.
1. RCU-014
S36
SYSTEM FAIL ALARM
When RPU-013 and RCU-014 cannot
communicate with each other due to a
1
problem on RPU-013, set whether to
output SYSTEM FAIL alarm signal from
RPU-014 or not
RELAY STATUS
2
Setting of polarity of the alarm signal
(relay output).
3
Unassigned
4
Unassigned
Function
Fig. 4.11.1 Location of RCU-014: S36
Table 4.11.1 Setting of RCU-014:S36
Setting
ON
Output
OFF
Do not output
Normally Close
ON
In the event of alarm,
relay is set to Open.
Normally Open
OFF
In the event of alarm,
relay is set to Close.
OFF
OFF
4-58
4.11 Alarm Output Setting
Factory
setting
ON
ON
OFF
OFF
J507: SYSTEM FAIL
S36 (DIP SW)