Tx-Hv Board (Hv-9017) - Furuno FAR-2107 Series Service Manual

Marine radar/arpa
Hide thumbs Also See for FAR-2107 Series:
Table of Contents

Advertisement

7.3.6 TX-HV board (HV-9017)

The setting of JP1 and JP2 on the TX-HV board differs depending on the radar TX
output of 10 kW and 25 kW or more. See page.4-69 for the related setting.
MAIN INV
J481
SW
1. +24V
(Q1:2SK1420)
2. -24V
-24V
CR6
(RD10EB1)
The TX-HV board is comprised of a main inverter and sub inverter. Each inverter is
controlled by U1 and the switching frequency is about 45 kHz and determined by R2, 3
and C7. U1 incorporates the IC for pulse length control of MB3757 with its peripheral
circuitry molded.
CR23 lights up when the power is supplied to this board and CR21 lights up when over
current of about 0.7 A is detected on the TX-HV. VR1 should be adjusted so that the
output voltage of the main inverter of TP-1 is 35 VDC. TX-HV voltage is set at JP1 and
JP2. The voltage setting is 310 to 350 VDC in case of a 10 kW –radar (FAR-2x17) and
520 to 580 VDC incase of radar of 25 kW or more (FAR-2x27).
SUB INB
TP3
TP1
(45kHz)
(+35V)
SW
(Q2:2SK1432)
REC
(CR3)
VR1
E1
SW CONT.
(U1:RC6220)
E2
PMW
Vcc
(MB3759)
RT
R2/3
-24V
TP2
-10V
Fig. 7.3.27 Block diagram of TX-HV board
7-69
T1
500V
300V
TP4
JP2
(45kHz)
330V
300V
260V
160V
160V
0
CR21
IN2
Over current
DET
CR23
CT
OC
DT
C7
C7
CR1
7.3 Processor Unit: RPU-013
REC
(CR11)
1. Tx-HV
JP1
500V
300V
REC
2. GND
(CR12)
U2
CR21(Red):Over Current
CR23(Green): Power IND
J482

Advertisement

Table of Contents
loading

Table of Contents