Extending Cables Between Antenna Unit And Processor Unit - Furuno FAR-2107 Series Service Manual

Marine radar/arpa
Hide thumbs Also See for FAR-2107 Series:
Table of Contents

Advertisement

3. Extending cables between Antenna unit and Processor unit

The Antenna cable; RW-9600 for connecting between the Transceiver/Antenna unit and
Processor unit is available in 15/30/40/50 m. (Available for max.100 m.)
Besides, extending the cable more than 100 m (Available for max.300 m.) is possible
with the Junction boxes: RJB-001 as shown below.
Applicable Model: FAR-2117, 2127, 2817 and 2827
RPU-013
Terminal p.c.b
J613
1. TX-HV
2. N.C
J610
1. 24V(+)
2. 24V(-)
3. Motor(+)
4. Motor(+)
5. Motor(-)
6. Motor(-)
7. SPU RF D-A
8. SPU RF D-B
9. RF SPU D-A
10. RF SPU D-B
11. Sig. GND
12. GND
J609
1. IF Vido in
2. GND
Applicable Model: FAR-2137S and 2837S
110 - 440VAC
3
50/60Hz
PSU-007
RPU-013
1. +12V
J604
2. ANT ON N
1. TX-HV
J613
2. N.C
J610
1. 24V(+)
2. 24V(-)
3.
4.
5.
6.
7. SPU RF D-A
8. SPU RF D-B
9. RF SPU D-A
10. RF SPU D-B
11. Sig. GND
12. GND
J609
1. IF Vido in
2. GND
Terminal p.c.b
RJB-001
RW-9600
TB-1
1. TX-HV
2. N.C
3. GND
4. 24V(+)
5. 24V(-)
6. Motor(+)
7. Motor(-)
8. Spare
9. Spare
10. SPU RF D-A
11. SPU RF D-B
12. SPU SPU D-A
13. SPU SPU D-B
14. Sig. GND
15. Spare
TB-2
1. IF-OUT
2. GND
RW-9600
Max. 15m
70 - 270m
Total: 100 - 300m
Fig. 1.2.4 Extension of Antenna Cable for FAR-2xx7
TPYCY-2.5
RJB-001
TB-1
RW-9600
1. TX-HV
DPYCY-6
2. N.C
3. GND
DPYCY-6
4. 24V(+)
5. 24V(-)
6.
7.
8. Spare
9. Spare
TTYCYS-4
10. SPU RF D-A
11. SPU RF D-B
12. SPU SPU D-A
13. SPU SPU D-B
14. Sig. GND
15. Spare
TB-2
RG-12/UY
1. IF-OUT
2. GND
RW-9600
Max. 15m
70 - 270m
Total: 100 - 300m
Fig. 1.2.5 Extension of Antenna Cable for FAR-2x37S
1-10
RJB-001
TB-1
RW-9600
DPYCY-6
1
2
3
DPYCY-6
4
5
DPYCY-6
6
7
8
9
TTYCYS-4
10
11
12
13
14
15
TB-2
RG-12/UY
1
2
RW-9600
Max. 15m
RJB-001
TB-1
RW-9600
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
TB-2
1
2
RW-9600
Max. 15m
1.2 Configuration
Antenna Unit
Terminal p.c.b
TB801
1. TX-HV
2. N.C
3. 24V(+)
4. 24V(-)
5. Motor(+)
6. Motor(+)
7. Motor(-)
8. Motor(-)
9. SPU RF D-A
10. SPU RF D-B
11. RF SPU D-A
12. RF SPU D-B
13.Sig. GND
14. GND
TB802
1. IF Vido in
2. GND
Antenna Unit
TB902
1. Motor 3ph u
2. Motor 3ph v
3. Motor 3ph w
Terminal p.c.b
TB801
1. TX-HV
2. N.C
3. 24V(+)
4. 24V(-)
5.
6.
7.
8.
9. SPU RF D-A
10. SPU RF D-B
11. RF SPU D-A
12. RF SPU D-B
13. Sig. GND
14. GND
TB802
1. IF Vido in
2. GND

Advertisement

Table of Contents
loading

Table of Contents