Control Terminal Block X2B; Digital Inputs; Figure 26: X2B Pluggable Terminal Block With Cage Clamp Terminals; Figure 27: Digital Inputs - KEB COMBIVERT P6 Instruction Manual

Hide thumbs Also See for COMBIVERT P6:
Table of Contents

Advertisement

Control circuit
4.3.6

Control terminal block X2B

Function
free
programmable,

digital inputs

Control release
Figure 26:
4.3.6.1 Digital inputs
Figure 27:
The digital inputs are specified in accordance with IEC61131-2 type 3. All 24 V terminals to-
gether are short circuit protected (250 mA).
36
Name Pin
DI 15
32
DI 14
30
DI 13
28
DI 12
26
DI 11
24
DI 10
22
DI 9
20
DI 8
18
DI 7
16
DI 6
14
DI 5
12
DI 4
10
DI 3
8
DI 2
6
DI 1
4
DI 0
2
X2B pluggable terminal block with cage clamp terminals
24V
DI0...DI15
Digital inputs
Input
Specification
Terminals
Pin Name Function
31
24 V
29
24 V
27
24 V
25
24 V
23
24 V
21
24 V
19
24 V
17
24 V
24 V outputs to supply
the digital inputs
15
24 V
13
24 V
11
24 V
9
24 V
7
24 V
5
24 V
3
24 V
1
24 V
DI 0...15
Status „0" -3...5 V
Status „1" 11...30 V
Iin: 4mA
DI0...15 X2B.2/4...32
24V X2B.1/3...31

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents