7.2 Advanced Settings (

7.2.1 Hold Settings (

This function sets the method for holding a judgment value (JUDGE.V).
To output normal measured values in real time, set the measurement mode to sample hold "S-
H" and leave external inputs turned OFF.
■ Measurement mode function (
This function allows you to select a hold mode from the following five types.
Measurement mode
(MEAS)
Sample hold
(S-H)
Peak hold (P-H)
Bottom hold (B-H)
Peak-to-peak hold
(P-P)
NG hold (NG-H)
■ External trigger input function
• Hold
If external trigger input turns ON, this function holds the judgment value (JUDGE.V) while
the input is ON.
WUME-HGT-3
)
This function holds and outputs the judgment value (JUDGE.V) only
when external input is ON.
When external input is OFF, the judgment value (JUDGE.V) is up-
dated as necessary before being output. (Real-time output)
When external input is turned ON, the maximum value during the
sampling period is held and output as the judgment value (JUDGE.
V). When external input is turned OFF, the maximum value during
the sampling period is continuously updated.
When external input is turned ON, the minimum value during the
sampling period is held and output as the judgment value (JUDGE.
V). When external input is turned OFF, the minimum value during
the sampling period is continuously updated.
The difference between the maximum value and minimum value is
held and output as the judgment value (JUDGE.V).
This function holds LOW judgment and HIGH judgment output.
ON
External trigger input
OFF
Setting up Extended Functions
)
)
Function
Hold
Hold
start
release
Reference page
Judgment value
(JUDGE.V)
Measured value
7-11
7-12
7-13
7-14
7-15
7-9

Advertisement