Setting up General Functions

6.4.9 Reference Waveform Save (

This function is only valid for communication commands from the host device.
Setting "BW.SAVE" (reference waveform save) to ON writes the reference waveform to the
EEPROM of the sensor head receiver when reference waveform registration is executed with a
communication command from the host device. Setting "BW.SAVE" (reference waveform save)
to OFF prevents the reference waveform from being written to the EEPROM.
If you turn OFF the power with "BW.SAVE" (reference waveform save) set to OFF, wave-
form data that is registered when reference waveform registration is executed with a com-
munication command from the host device will not be saved into the EEPROM of the sensor
head receiver. If you need to save the waveform data, be sure to set "BW.SAVE" (reference
waveform save) to ON.
<Reference>
● The EEPROM of the sensor head receiver can be rewritten approximately one million times.
Pay attention to the upper limit to the number of save operations. If there is no need to save ref-
erence waveforms, set "BW.SAVE" (reference waveform save) to OFF.
● Reference waveforms that are registered through key operations or PC tools will be saved into
the EEPROM regardless of the set value.
Setting method
Hold down for 2 seconds
Setting item
Reference waveform save (BW.SAVE)
6-26
)
Set value
Reference waveform save OFF (OFF)
Reference waveform save ON (ON)