5.3.4 Teaching

<Overview>
Set the HIGH set value and LOW set value. The range between the LOW set value and the
HIGH set value is set as GO range. Values within GO range are judged to be "GO", and values
outside GO range are judged to be out-of-range (on LOW or HIGH side).
Term
GO
<Settings>
Teaching type
1-point teaching
(Default)
2-point teaching
3-point teaching
(Note): Upper and lower limit values are regarded as HIGH and LOW set values, respectively.
<Reference>
The default setting for the tolerance is "0.100" (±0.100).
WUME-HGT-3
Refers to the judgment range between the HIGH set value and LOW set value.
Emitter
You can use a master workpiece to set upper and lower limit values.
Use this method when you want to set judgment values for the workpiece as ± tolerance.
You can use two workpieces to set upper and lower limit values.
Use this method when you want to judge workpieces within an upper limit and lower limit
range.
You can use a good workpiece, a HIGH-side defective workpiece, and a LOW-side defec-
tive workpiece to set upper and lower limit values.
Use this method when you want to judge workpieces within a range that takes the inter-
mediate values between good and HIGH-side or LOW-side defective workpieces as upper
and lower limits.
Description
Measured object
Receiver
Setting method
+0.100
Tolerance
Tolerance
-0.100
Basic Usage
Upper limit value
Judgment value
Lower limit value
Upper limit value
Lower limit value
Maximum value
Upper limit value
Median value
Lower limit value
Minimum value