Chapter 3 Function

3-3-4 Data Processing Settings

 Average Times
This function is used to set the average number of times of moving average. Use
the function to stabilize unstable measurement values (including variations).
1 time
4 times
16 times
64 times
256 times
1024 times
*
3
Data unstability may result until the movement average buffer reaches the setting
number of times (
Unfixed"). If there is an alarm when the moving average buffer is cleared, moving
averaging will start after the alarm state is cleared. Moving averaging based on the
previous data will be performed if an alarm occurs until the setting number of
times is reached after moving averaging starts.
● Setting Procedure
1
2
3
4
5
Setting
1-time moving average processing
4-time moving average processing
16-time moving average processing
64-time moving average processing
256-time moving average processing
1024-time moving average processing
indicates the default value.
refer to "2-5 Conditions When Output Data Become
Display the "Data Processing Setting"
screen while the system is in setting mode.
Press the [ENTER] key. The "Average
Times" screen will be displayed.
Press the [ENTER] key. The present
number of average times will be displayed.
Press the [UP]/[DOWN] key to change
the number of average times.
(Example: Changing the number of
average times to 256.)
Press the [ENTER] key and determine
the number of average times.
Function
3-16