Diagram of Functions and Settings

2-1. Diagram of Functions and Settings
The amplifier of LS-400 series features and settings are generally classified into two main modes; the 'NAVI' mode
for items and settings that are frequently reconfigured, and the 'PRO' mode that contains more detailed settings.
RUN
This indicates normal sensing
operation. The threshold value
can be fine-adjusted as well.
NAVI
mode
PRO
Allows various detailed settings to be
configured, such as optical communications,
save / load and other settings.
PRO1
PRO2
PRO3
PRO
mode
PRO4
PRO5
PRO6
Ramco National
Run
Pro
Response time change
Switches among response
times. (Refer to p. 25.)
P. 24l
Display switching
This selects whether the digital display
is fixed at digits, % or peak hold / bottom
P. 30l
hold display, or whether the display can
be selectable. (Refer to p. 32.)
Stored value comparison
This simultaneously displays the saved incident
light intensity and the current incident light
intensity for checking things such as drops in
incident light intensity. (Refer to p. 37.)
Data bank load
Loads configuration setting from the data
bank. Select only one amplifier to load or all
P. 38l
amplifiers connected on the right side of the
main unit to load in a single step by using
optical communications. (Refer to p. 39.)
Copy
Using optical communications,
configuration settings from the
P. 41l
main unit are copied to units
connected on the right side of
the main unit, in a single step.
(Except data bank load / save,
0-adjust function setting and
transmission change to permit /
not to permit.) (Refer to p. 42.)
Coding
Allows
basic
configuration
information to be set in a single
P. 46l
step, by inputting a 8-digit code.
(Refer to p. 48.)
Normal mode
Sets a threshold value for ON /
OFF operation.
P. 52l
mFor
mFor output 1
output 2
(
Refer to
)
p. 55.
Output 2 OFF
Set to OFF when not using
output 2.
(800) 280-6933
Teaching
TEACH
The threshold value can be set by utilizing
either '2-level / limit / full-auto teaching'. When
the sensor is in window comparator / hysteresis
mode, the threshold value can be set by either
'1-level / 2-level / 3-level teaching'. When using
rising / trailing differential mode, 'span
adjustment' is carried out. (Refer to p. 11.)
Custom
CUST
Shows stored settings for functions.
(Refer to p. 10.)
Hysteresis
Sets hysteresis. (Refer to p. 26.)
Emission halt
Selects
laser
emission
execute or halt. (Refer to p. 29.)
Display turning
Sets the viewing orientation of the
digital display. (Refer to p. 33.)
Current value
storage
Saves current incident light
intensity. (Refer to p. 36.)
Data bank save
Saves configuration setting from the data
bank. Select only one amplifier to save or all
amplifiers connected on the right side of the
main unit to save in a single step by using
optical communications. (Refer to p. 40.)
Transmission change
to permit / not to permit
Allows to ignore copy / load /
save operations in a single step
used by optical communications.
(Refer to p. 43.)
0-adjust setting
Forces the numerical value for
incident light intensity to '0' on the
digital display. (Refer to p. 49.)
Window comparator mode
Judges if set two threshold values
are within the required range or not.
This can be selected in 1-level /
2-level / 3-level teaching.
Refer to
(
)
p. 53l.
Hysteresis mode
Changes hysteresis to ignore
small change of incident light
intensity. This can be selected in
1-level / 2-level / 3-level teaching.
2
L-ON / D-ON
L/D ON
Sets output operation either
Light-ON, or Dark-ON. (Refer to
p. 22.)
Timer
TIMER
Configures operation and period
of the timer. (Refer to p. 23.)
Shift
Shifts the 'threshold value' by a
certain percentage increment in
'limit teaching'. (Refer to p. 27.)
M.G.S.
to
Sets receiving light sensitivity
in 3 level (U-LG mode: 4-level).
(Refer to p. 28.)
ECO mode setting
Sets the digital display to turn
ON / OFF. (Refer to p. 34.)
Period hold
Selects to display peak / bottom
values in the hold condition or
peak / bottom values in the digital
display
refleshing
condition.
(Refer to p. 35.)
mCable type only
External input
switch setting
Using external input wire,
'emission
halt',
'full-auto
teaching' or 'limit teaching' is
selected. (Refer to p. 44.)
mCable type only
Backup setting
Allows not to save the threshold
value, by teaching via external
input, in EEPROM. (Refer to p. 45.)
Reset
All settings, except for data
bank, revert to factory settings.
(Refer to p. 50.)
CUSTOM mode display
Selects a function in CUSTOM
mode to display. (Refer to p. 51.)
Rising differential mode
Sensing mode that cancels out
slight changes in light intensity so
that only sudden increases in
incident light intensity are sensed.
Trailing differential mode
Sensing mode that cancels out
slight changes in light intensity so
that only sudden decreases in
incident light intensity are sensed.
www.pansonicsensors.com