Mounting The Side View Attachment - Panasonic HG-T Series User Manual

Thru-beam type digital displacement sensor
Hide thumbs Also See for HG-T Series:
Table of Contents

Advertisement

4.5 Mounting the Side View Attachment

● Take care that the beam axis can be adjusted after a side view attachment is mounted on
the emitter.
● After mounting a side view attachment on the sensor head, check whether the beam axis
is aligned. After checking the beam axis, always register the reference waveform and
check operations.
Mounting side view attachment HG-TSV10 on sensor head HG-T1010 makes various installa-
tions possible. (Note 1)
When mounting a side view attachment on the sensor head, use the M2 screws with a washer
(length: 4mm) provided.
Tighten the screws to a torque of 0.088 N-m or less.
Notes: 1) Side view attachments cannot be mounted on sensor head HG-T1110 (measurement width 10 mm, slim
type).
2) HG-TSV10 is sold by one unit. Two pieces of attachment are required when using the attachment on
both emitter and receiver.
WUME-HGT-3
Sensor head
Side view attachment
HG-TSV10
M2 screw with washer
(length: 4mm)(Accessory)
Installation and Connections
<Example of HG-TSV10 mounted on both sides> (Note 2)
Emitter
HG-TSV10
HG-TSV10
Receiver
4-15