Command Manual – RPR
H3C S9500 Series Routing Switches
Parameters
string: Station name, a string consisting of up to 20 bytes.
Description
Use the rpr station-name command to configure a station name.
Use the undo rpr station-name command to remove the configuration.
Examples
# Name the local station as hangzhou.
<H3C> system-view
[H3C] interface RprPos2/1/1
[H3C-RprPos2/1/1] rpr station-name hangzhou

1.1.30 rpr timer

Syntax
rpr timer { atd value | fdd value | holdoff value | stability value | tp-fast value |
tp-slow value | tc-fast value | tc-slow value | wtr value | keepalive value | mac-aging
value }
undo rpr timer { atd | fdd | holdoff | stability | tp-fast | tp-slow | tc-fast | tc-slow | wtr
| keepalive | mac-aging }
View
RPR logical interface view
Parameters
atd value: Sets the ATD timer. The value argument ranges from 1 to 200 (in 50 ms). The
system default is 20, meaning one second..
fdd value: Sets the FDD timer. The value argument ranges from 10 to 1,000 (in
milliseconds).
holdoff value: Sets the hold-off timer. The value argument ranges from 0 to 50 (in 10
milliseconds). The system default is 0.
stability value: Sets the stability timer. The value argument ranges from 10 to 100 (in
milliseconds).
tp-fast value: Sets the TP-fast timer. The value argument ranges from 1 to 20 (in
milliseconds).
tp-slow value: Sets the TP-slow timer. The value argument ranges from 1 to 200 (in 50
ms). The system default is 20, meaning one second.