H3C S9500 Series Command Manual
H3C S9500 Series Command Manual

H3C S9500 Series Command Manual

Routing switches
Hide thumbs Also See for S9500 Series:

Advertisement

Quick Links

Command Manual - Clock Monitoring
H3C S9500 Series Routing Switches
Chapter 1 Clock Monitoring Configuration Commands ............................................................ 1-1
1.1 Clock Monitoring Configuration Commands ...................................................................... 1-1
1.1.1 clock ........................................................................................................................ 1-1
1.1.2 clock forcessm......................................................................................................... 1-2
1.1.3 clock lpuport ............................................................................................................ 1-3
1.1.4 clock priority ............................................................................................................ 1-4
1.1.5 clock sa-bit .............................................................................................................. 1-4
1.1.6 clock ssm................................................................................................................. 1-5
1.1.7 clock ssmcontrol...................................................................................................... 1-6
1.1.8 clock stop warm-up ................................................................................................. 1-7
1.1.9 display clock basephase ......................................................................................... 1-8
1.1.10 display clock config ............................................................................................... 1-8
1.1.11 display clock d/a .................................................................................................. 1-10
1.1.12 display clock device ............................................................................................ 1-10
1.1.13 display clock lpuport............................................................................................ 1-13
1.1.14 display clock phase-lock-state ............................................................................ 1-14
1.1.15 display clock priority ............................................................................................ 1-15
1.1.16 display clock self-test-result ................................................................................ 1-16
1.1.17 display clock source ............................................................................................ 1-17
1.1.18 display clock ssm-level........................................................................................ 1-18
1.1.19 display clock ssm-output ..................................................................................... 1-19
1.1.20 display clock version ........................................................................................... 1-20
1.1.21 display clock work-mode ..................................................................................... 1-21

Table of Contents

i
Table of Contents

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the S9500 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for H3C S9500 Series

  • Page 1: Table Of Contents

    Command Manual – Clock Monitoring H3C S9500 Series Routing Switches Table of Contents Table of Contents Chapter 1 Clock Monitoring Configuration Commands ............1-1 1.1 Clock Monitoring Configuration Commands ..............1-1 1.1.1 clock ........................1-1 1.1.2 clock forcessm......................1-2 1.1.3 clock lpuport ......................1-3 1.1.4 clock priority ......................
  • Page 2: Chapter 1 Clock Monitoring Configuration Commands

    If the SRPUs are not installed with a clock module, all these commands are invisible. For information about SRPUs installed with a clock module, refer to the S9500 Series Routing Switches Installation Manual. 1.1 Clock Monitoring Configuration Commands 1.1.1 clock...
  • Page 3: Clock Forcessm

    Command Manual – Clock Monitoring Chapter 1 Clock Monitoring Configuration H3C S9500 Series Routing Switches Commands Note that: Before configuring the work mode as manual, you should use the display clock source command to view the clock source state. Only clock sources working normally can be successfully configured as the primary clock source.
  • Page 4: Clock Lpuport

    Command Manual – Clock Monitoring Chapter 1 Clock Monitoring Configuration H3C S9500 Series Routing Switches Commands <Sysname> system-view [Sysname] clock forcessm off source 1 1.1.3 clock lpuport Syntax clock lpuport interface-type interface-number undo clock lpuport interface-type interface-number View System view...
  • Page 5: Clock Priority

    Command Manual – Clock Monitoring Chapter 1 Clock Monitoring Configuration H3C S9500 Series Routing Switches Commands 1.1.4 clock priority Syntax clock priority value source source-number undo clock priority source source-number View System view Default Level 2: System level Parameters value: Priority value.
  • Page 6: Clock Ssm

    Command Manual – Clock Monitoring Chapter 1 Clock Monitoring Configuration H3C S9500 Series Routing Switches Commands sa5: Indicates that the bit position is sa5. sa6: Indicates that the bit position is sa6. sa7: Indicates that the bit position is sa7.
  • Page 7: Clock Ssmcontrol

    Command Manual – Clock Monitoring Chapter 1 Clock Monitoring Configuration H3C S9500 Series Routing Switches Commands Description Use the clock ssm command to set the SSM levels of the reference sources. Use the undo clock ssm command to restore the default.
  • Page 8: Clock Stop Warm-Up

    Command Manual – Clock Monitoring Chapter 1 Clock Monitoring Configuration H3C S9500 Series Routing Switches Commands Use the undo clock ssmcontrol command to restore the default. By default, SSM level is deactivated. Note that: When SSM level is activated, the SSM level becomes the decisive factor in reference source automatic selection.
  • Page 9: Display Clock Basephase

    Command Manual – Clock Monitoring Chapter 1 Clock Monitoring Configuration H3C S9500 Series Routing Switches Commands 1.1.9 display clock basephase Syntax display clock basephase View Any view Default Level 1: Monitor level Parameters None Description Use the display clock basephase command to view the synchronized clock base phase.
  • Page 10 Command Manual – Clock Monitoring Chapter 1 Clock Monitoring Configuration H3C S9500 Series Routing Switches Commands Examples # View the current configurations of the clock monitoring module. <Sysname> display clock config Clock module current configuration: Work mode : auto SSM participate in control : no...
  • Page 11: Display Clock D/A

    Command Manual – Clock Monitoring Chapter 1 Clock Monitoring Configuration H3C S9500 Series Routing Switches Commands Field Description Bits used to transmit SSM level information Sa-bit of the Bits clock source Input port of the line clock source (N/A Lpu port indicates this function is not supported and (;) indicates this port is not configured)
  • Page 12 Command Manual – Clock Monitoring Chapter 1 Clock Monitoring Configuration H3C S9500 Series Routing Switches Commands Default Level 1: Monitor level Parameters None Description Use the display clock device command to view detailed information of the clock monitoring module. Examples # View detailed information of the clock monitoring module.
  • Page 13 Command Manual – Clock Monitoring Chapter 1 Clock Monitoring Configuration H3C S9500 Series Routing Switches Commands lost UNKNOWN lost UNKNOWN lost UNKNOWN lost UNKNOWN lost UNKNOWN lost UNKNOWN lost UNKNOWN lost UNKNOWN lost UNKNOWN lost UNKNOWN lost UNKNOWN Table 1-2 display clock device command output description...
  • Page 14: Display Clock Lpuport

    Command Manual – Clock Monitoring Chapter 1 Clock Monitoring Configuration H3C S9500 Series Routing Switches Commands Field Description Priority Priority of the reference source SSM-level SSM of the reference source Whether the SSM level of the reference Forcessm source is activated or not...
  • Page 15: Display Clock Phase-Lock-State

    Command Manual – Clock Monitoring Chapter 1 Clock Monitoring Configuration H3C S9500 Series Routing Switches Commands Field Description Input port of the line clock source (port Lpu port (portname) name) 1.1.14 display clock phase-lock-state Syntax display clock phase-lock-state View Any view...
  • Page 16: Display Clock Priority

    Command Manual – Clock Monitoring Chapter 1 Clock Monitoring Configuration H3C S9500 Series Routing Switches Commands 1.1.15 display clock priority Syntax display clock priority View Any view Default Level 1: Monitor level Parameters None Description Use the display clock priority command to view the priority of all reference sources.
  • Page 17: Display Clock Self-Test-Result

    Command Manual – Clock Monitoring Chapter 1 Clock Monitoring Configuration H3C S9500 Series Routing Switches Commands 1.1.16 display clock self-test-result Syntax display clock self-test-result View Any view Default Level 1: Monitor level Parameters None Description Use the display clock self-test-result command to view the self-test result of the clock monitoring module.
  • Page 18: Display Clock Source

    Command Manual – Clock Monitoring Chapter 1 Clock Monitoring Configuration H3C S9500 Series Routing Switches Commands Field Description PLL TRU050 PLL TRU050 state PLL 88915 PLL 88915 state OSC state I2C bus I2C bus state EPLD EPLD state HDLC HDLC state...
  • Page 19: Display Clock Ssm-Level

    Command Manual – Clock Monitoring Chapter 1 Clock Monitoring Configuration H3C S9500 Series Routing Switches Commands lost lost lost lost lost lost lost lost lost lost lost lost lost Table 1-6 display clock source command output description Field Description No primary reference is traced, meaning no No primary reference is traced primary reference is manually specified.
  • Page 20: Display Clock Ssm-Output

    Command Manual – Clock Monitoring Chapter 1 Clock Monitoring Configuration H3C S9500 Series Routing Switches Commands Related commands: clock ssm. Examples #View the SSM level of all reference sources. <Sysname> display clock ssm-level Reference SSM level UNKNOWN UNKNOWN UNKNOWN UNKNOWN...
  • Page 21: Display Clock Version

    Command Manual – Clock Monitoring Chapter 1 Clock Monitoring Configuration H3C S9500 Series Routing Switches Commands Description Use the display clock ssm-output command to view the SSM level of the output clock signal. Examples # View the SSM level of the output clock signal.
  • Page 22: Display Clock Work-Mode

    Command Manual – Clock Monitoring Chapter 1 Clock Monitoring Configuration H3C S9500 Series Routing Switches Commands Field Description CPLD version CPLD version of the clock monitoring module Release date Release version of the clock monitoring module 1.1.21 display clock work-mode...

Table of Contents