Minimum
Maximum
value
value
1
255
6.6.1.3
This parameter indicates frequency (time interval in seconds) of sending data to server.
Minimum
Maximum
value
value
0
2592000

6.6.2 Home Network GSM operator code "Vehicle MOVING" parameters

6.6.2.1
This parameter indicates time interval in seconds in order to acquire new record. If value is
0 it means no records by min period will be saved.
Minimum
Maximum
value
value
0
2592000
6.6.2.2
This parameter indicates distance in meters in order to acquire new record. Record is
stored when the distance between previous records is greater than parameters value. If value is
0 it means no records by min distance will be saved.
Minimum
Maximum
value
value
0
65535
6.6.2.3
This parameter indicates angle in degrees in order to acquire new record. If angle
difference between last recorded coordinate and current position is greater than defined value,
new record is stored. This parameter is operational, when speed is higher than 10km/h. If value
is 0 it means no records by min angle will be saved.
Minimum
Maximum
value
value
0
180
6.6.2.4
This parameter indicates speed difference in order to acquire new record. If speed
difference between last recorded coordinate and current position is greater than defined value,
new record is stored. If value is 0 it means no records by min distance will be saved.
Recommended
Goes with (depends on)
value
1

Send Period (ID=10005)

Recommended
value
-
Min Saved Records (ID=10004)

Min Period (ID=10050)

Recommended
value
-

Min Distance (ID=10051)

Recommended
Goes with (depends on)
value
-

Min Angle (ID=10052)

Recommended
Goes with (depends on)
value
-
Min Distance (ID=10051)

Min Speed delta (ID=10053)

parameters
Goes with (depends on)
parameters
Goes with (depends on)
parameters
Min Distance (ID=10051)
Min Angle (ID=10052)
parameters
Min Period (ID=10050)
Min Angle (ID=10052)
parameters
Min Period (ID=10050)
Value
type
U8
Value
type
U32
Value
type
U32
Value
type
U32
Value
type
U16