5.9.3 Unplug Detection

Eventual event will be generated when FMB001 is unplugged from OBD socket.
Unplug detection mode:
Simple – makes event according to external voltage loss
Advanced – makes event according to external voltage and accelerometer.

5.9.4 Crash detection

Crash
Detection
Threshold (mg)
Duration
(ms)
If accident happens and FMB001 detects acceleration value higher than set threshold value
during set time period, then device will generate an event. Threshold and duration values are set
depending of accident power which you want to detect. FMB001 can detect a slight tapping on the
device (Threshold=100mg, Duration=1ms) or can detect severe accident (Threshold=4000mg,
Duration=5ms)..
Figure 8 Unplug detection
Figure 9 Crash detection
functionality
can
be
set
according
to
these
settings: