Excessive Idling Priority (Id=11200); Eventual Records (Id=11203); Excessive Idling Minimum Stop Duration (Id=11205); Excessive Idling Minimum Move Duration (Id=11206) - Teltonika FMB001 User Manual

Gnss/gsm terminal, internal li-ion battery 3.7v, 170mah
Hide thumbs Also See for FMB001:
Table of Contents

Advertisement

6.7.12 Excessive idling priority (ID=11200)

Defines priority of Excessive idling scenario:
0 – disabled, 1 – low, 2 – high, 3 – panic
Minimum
Maximum
value
value
0
3

6.7.13 Eventual records (ID=11203)

Disables (0) or enables (1) eventual records with idling value
Minimum
Maximum
value
value
0
1

6.7.14 Excessive idling minimum stop duration (ID=11205)

Defines minimum time in seconds of vehicle idling before scenario enables.
Minimum
Maximum
value
value
0
255

6.7.15 Excessive idling minimum move duration (ID=11206)

Defines minimum time in seconds of vehicle idling before scenario disables.
Minimum
Maximum
value
value
0
255

6.7.16 Jamming (ID=11300)

Scenario settings: 0 – Disable, 1 – Low, 2 – High, 3 – Panic
Minimum
Maximum
value
value
0
3

6.7.17 Jamming Eventual records (ID=11303)

Disables or enables eventual records. 0 – Disable, 1 – Enable
Minimum
Maximum
value
value
0
1

6.7.18 Trip priority priority (ID=11800)

Defines priority of trip scenario:
Recommended
Goes with (depends on)
value
-
Recommended
Goes with (depends on)
value
-
Default value
Goes with (depends on)
5
Default value
Goes with (depends on)
2
Default value
Goes with (depends on)
0
Default value
Goes with (depends on)
1
parameters
parameters
parameters
parameters
parameters
parameters
Value
type
U8
Value
type
U16
Value
type
Float
Value
type
Float
Value
type
U8
Value
type
U8
81