RPM, 10 - Accelerometer or Engine RPM, 11 - DIN1, Accelerometer or Engine RPM, 12 - Power
Voltage or Engine RPM, 13 -DIN1, Power Voltage or Engine RPM, 14 - Accelerometer, Power
Voltage or Engine RPM, 15 - DIN1, Accelerometer, Power Voltage or Engine RPM.
1
15
6.2.9 High voltage level (ID=104)
Sets high level of voltage if ignition settings is set to power voltage.
0
6.2.10 Low voltage level (ID=105)
Sets low level of voltage if ignition settings is set to power voltage.
0
29999
6.2.11 Led indication (ID=108)
Sets led indication: 0 - disabled, 1 - enabled
Minimum
Maximum
value
value
0
1
6.2.12 Battery charge mode (ID=110)
Sets battery charge mode: 0 - on need, 1 - After ignition ON.
Minimum
Maximum
value
value
0
1
6.2.13 Synchronization settings (ID=900)
Settings used for device internal time synchronization: 0 - GPS only, 1 - NITZ and NTP, 2 -
NTP, 3 - NITZ.
Minimum
Maximum
value
value
0
3
4
Recommended
value
30000
Recommended
value
13000
Recommended
Goes with (depends on)
value
1
Default value
Goes with (depends on)
0
Default value
Goes with (depends on)
1
parameters
parameters
parameters
U8
U8
Value
type
U8
Value
type
U8
Value
type
Uint8