Shutter Open/Close - Panasonic VL-W1 Series Setup And Maintenance Manual

Laser processing machine
Table of Contents

Advertisement

4-6-2 Shutter open/close

LASER SUPPLY IN (X9)
TRIGGER IN (X6)
SHUTTER ENABLE IN (X11)
SHUTTER IN (X10)
SHUTTER OPEN OUT (Y10)
SHUTTER CLOSE 1 OUT
SHUTTER CLOSE 2 OUT
READY OUT (Y6)
LASING OUT (Y7)
LASING END OUT (Y8)
*1 : SHUTTER IN (X10) is accepted and the shutter opens only when SHUTTER ENABLE IN (X11) is turned on.
*2 : If SHUTTER IN (X10) was turned off during the lasing operation, the shutter closes after the lasing operation has
completed.
Item
Time
T1
Around 200ms to
max. 1 sec.
T2
T3
10 ms or more
T4
T5
20 to 510 ms
ON
OFF
ON
OFF
ON
OFF
*1
ON (Open)
OFF (Close)
ON (Open)
OFF (Close)
ON (Close)
OFF (Open)
ON (Close)
OFF (Open)
ON
OFF
ON
OFF
ON
OFF
Remarks
SHUTTER OPEN OUT (Y10) and SHUTTER CLOSE 1&2 OUT (Shutter close output
terminal No.2, 3) have a delay time of up to one second from turning ON of SHUTTER IN
(X10) for the actual shutter open / close operation time.
SHUTTER OPEN OUT and SHUTTER CLOSE 1&2 OUT will be output by the same
operation, but their output timing has a margin of error.
Setup time of the laser processing machine to start the lasing operation.
• In the laser pumping completed state: Time for data creation. It varies depending on the
quantity of the setting data.
Keep the ON status for 10 ms or more.
When TRIGGER IN (X6) is accepted, LASING OUT (Y7) is turned ON.
One-shot output. Set the output time on the environment setting screen.
There is a small margin of error for the setting value.
ME-VLW1-SM-8
T1
T1
T1
T1
T1
T2
T2
T2
T3
*2
T1
T4
T5
113

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Vl-w1500Vl-w1a00Vl-w1506Vl-w1a06

Table of Contents