4.5.1 Continuous Transient Operation

Press [Shift] +[2] (Tran) to enter the transient operation setup menu:
Steps
Press
1
[
[Enter] to confirm.
Preess
transient
2
CONTINUOUS
Trig will be lighted)
Set the rising slope,press [Enter] to
3
confirm
Set the descending slope,press
4
[Enter] to confirm
Set level A,press [Enter]
5
confirm
6
Set level B,press [Enter] to confirm
Set the frequency,press [Enter] to
7
confirm
Set the dutyfactor,press [Enter] to
8
confirm
Open the transient test function,
9
mentain on the "on"selection, press
[Enter] to confirm.
Then the VFD will display
10
and
Trig
Turn on the load, press [Shift]+[
11
(Trigger) to trigger
Press anyone of [CC/CV/CW/CR] button can quit the transient test,if you
12
want to continue the test again, please repeat 1-11 steps
Operation
[Shift]+[2]
(Tran),
move
] key to select ON., press
[
]
to
select
operation
mode
(the indicator lamp
TRAN A
Copyright © Itech Electronics Co., Ltd.
VFD Display
TRAN
ON
MODE CONTINUOUS >
as
UP=1A/uS
DOWN=2/uS
to
LEVEL A=5A
LEVEL B=10A
FREQUNCE=50HZ(0.01-10000HZ)
DUTY=98%(%0.1-99.9%)
TRAN
ON
10.0000V 0.0000A
0.00W
TRAN.
Trig
]
Basic Operation
OFF
OFF
0