Press [Shift]+[2] (Tran) to enter the transient operation setup menu
Steps

4.6 List Operation

Before run a list file,you should edit the list file firstly and save it in a non-volatile
memory.The following examples will help you understand the function well.In
the example, the output voltage and current are 10V and 3A,and the DC load is
in CC mode.
TRG
Toggled Transient Operation
Operation
Press [Shift]+[2] (Tran), move
1
[
] key to select on.,
press [Enter] to confirm.
2
Set transient operation mode as
TOGGLE(the
Trig will be lighted)
3
Set the rising slope, press
[Enter] to confirm.
4
Set the descending slope,press
[Enter] to confirm
Set level A, press [Enter] to
5
confirm
Set level B, press [Enter] to
6
confirm
7
Open the transient test function,
function,press
confirm
8
Then the VFD will display
TRAN
and
Trig
9
Turn
on
[Shift]+[
] (Trigger) to trigger
Press anyone of [CC/CV/CW/CR] button will quit the
10
transient test,if you want to continue the test again,please
repeat 1-9 steps.
Copyright © Itech Electronics Co., Ltd.
TRG
indicator
lamp
[Enter]
to
the
load,
press
Basic Operation
VFD Display
TRAN
On
Off
MODE
CONTINUOUS >
UP=1A/US
DOWN=2A/US
LEVEL A=5A
LEVEL B=10A
TRAN
ON
OFF
10.0000V 0.0000A
0.00W
TRAN.
Trig
0
35

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IT8500plus Series and is the answer not in the manual?

Questions and answers

Table of Contents