Page 1
Via Acquanera, 29 22100 Como tel. 031.526.566 (r.a.) fax 031.507.984 info@calpower.it www.calpower.it Programmable DC Electronic Load Series IT8800 User’s Manual Model: IT8813/IT8813B/IT8813C/IT8814/IT8814B/ IT8814C/IT8816/IT8816B/IT8816C/IT8817/ IT8817B/IT8817C/IT8818/IT8818B/IT8818C/ IT8818D/IT8830/IT8830B/IT8830H/IT8831/ IT8831B/IT8831H/IT8832/IT8832B/IT8832H/ IT8833/IT8833B/IT8833H/IT8834B/IT8834H/ IT8835B/IT8835H/IT8836B/IT8836H/IT8837B/ IT8837H/IT8838B/IT8838H/IT8839B/IT8839H/ IT8819H Revision: V3.2...
Page 2
“Caution” signs indicate danger. It is extent of laws, ITECH is not committed languages of other countries or regions) required to pay attention to the contents to any explicit or implied guarantee for...
ITECH, and ITECH will be responsible for return freight. If the product is sent to ITECH for warranty service from other countries, the customer will be responsible for all the freight, duties and other taxes. Limitation of Warranty...
Do not block the air vent of the equipment. Environmental conditions The IT8800 series electronic load can only be used indoors or in low condensation areas. The following table shows general environmental requirements for this instrument. Environmental conditions...
Working voltage of IT8800 series includes 110V and 220V (which can be selected by the switch on rear board of load). When IT8800 series load power is greater than or equal to 35KW, the 110V AC power input is not supported. AC power input level: ...
Quick Start Chapter2 Quick Start This Chapter will introduce power-on check steps of IT8800 Series to ensure normal start-up and usage under initialization status of the load. Besides, to facilitate usage, this part also displays the functions of front board, rear board...
5. Numeric keys, Esc keys and composite keys 6. Arrow Keys and Enter Key 2.3 Introduction to the keypad The keypad of IT8800 series is shown in the next figure. The following table explains the keys and buttons on the keypad. Shift Enables access to secondary functions.
Rotary knob to adjust the setups by 1 stepping. ×1 2.4 Fast function key A combination of front board keys and Shift composition keys in IT8800 Series can realize functions marked at key bottom. For details, see table below. To start or end short circuit test.
3.10 OCP test function The IT8800 series electronic load is provided with over-current protection test function (OCP). Under OCP test mode, when input voltage reached Von value, delay for a while for the electronic load to latch. Ascend value by step value at regular interval.
STOP 3.11 OPP test function The IT8800 series electronic load is provided with overpower protection test function (OPP). Under OPP test mode, when input voltage reached Von value, delay for a while for the electronic load to latch. Ascend value by step value at regular interval.
FAULT STOP 3.12 Battery discharge test function In the IT8800 series electronic load, constant current mode is applied for capacity test with programmatic setting of cutoff level/capacity/discharging time If cutoff level is set as the stop condition, the system determines whether the battery is about to reach the set threshold value or unsafe status when the battery voltage is low, and if yes, an automatic stop will be activated.
Press [Esc] key to exit battery capacity test mode in any three methods. 3.13 CR-LED test function With adding of diode break-over voltage setting in the IT8800 series electronic load under conventional CR mode, the electronic load only works when voltage applied at its both ends is higher than the diode break-over voltage to give a real simulation of diode working principle, i.e., the ripple current at real LED...
In the example: Vd=50V*0.8=40V R=(0.2*50V)/0.2A=50Ω. 3.14 Measurement of voltage rise time The IT8800 series electronic load is provided with special voltage rise/drop time measurement function. This function gives a simple analog of voltage rise/drop speed of oscilloscope test power. Operation methods: Set initial voltage and final voltage Press [Shift] + 6 keys to enter configuration menu.
1 of the interface and switch CV mode through pin 6. 3.21 Auto test function The IT8800 series electronic load delivers strong auto test functions, which can analog several tests. A total of 10 groups of test files can be edited, and each group test file has 10 steps.
EIA RS-232, the load is connected to another DTE (e.g., PC COM interface) with direct-connected Modem cable. NOTE The rear board of IT8800 series has two COM interfaces. The upper 9-pin COM interface connector is RS232 interface; and the lower 9-pin COM interface is external signal control interface.
Specifications of Red and Black Test Lines ITECH provides you with optional red and black test lines, which individual sales and you can select for test. For specifications of ITECH test lines and maximum current values, refer to the table below.
Page 92
Contact Us Thanks for purchasing ITECH products. In case of any doubts, please contact us as follows: 1. Refer to accompanying data disk and relevant manual. 2. Visit ITECH website: www.itechate.com. 3. Select the most convenient contact method for further information.