Special function
FINAL CRATER TIME
BURN BACK
POST GAS
FIRST SLOPE ( I
TO I
)
1
2
CYCLE WIRE SPEED
CYCLE VOLTAGE
SECOND SLOPE ( I
TO I
)
2
1
ACS / ENCODER SPEED
WARNING:
• The STANDARD or ADVANCED welding CYCLE mode can only be activated by opening the ADVANCED SETUP Menu - AD-
VANCED MODE - CYCLE (for further explanations, see the relevant paragraph).
• It is possible to access editing of the SPECIAL FUNCTIONS (Fx) during welding.
• Some of the values edited will be used immediately by the operator, while others will be active from when the next welding
task begins.
• The HOLD function is not active within the SPECIAL FUNCTIONS Menu (SET UP Fx).

3 - PRE-SETTING

ENCODER K
MENU K
EY
ENCODER K
- SX
NOB
DX K
EY
ENCODER K
- DX
NOB
PARAMETER DISPLAY
Screen - A
F15
bub
PoG
F18
F19
F20
F21
F28
"DH" CONTROL PANEL
MENU K
EY
SX K
EY
- SX
NOB
Used to access the PROCESS SELECTION Menu (PROCESS) and subsequent menus, as
applicable.
Adjusts the parameter selected using the SX K
Scrolls in succession WELDING VOLTAGE ( ) - ELECTRONIC INDUCTANCE (
VISION S
(this operation is activated when the key is released).
CREEN
Adjusts the parameter selected using the DX K
PARAMETER DISPLAY Screen - V
0.0s
(0.0 - 5.0)s
0
-30 - +30
1.0s
(0.0 - 10.0)s
0.05s
(0.0 - 1.0)s
5.0m/min
(0.6 - MAX)m/min
25.0V
(min - MAX)V
0.05s
(0.0 - 1.0)s
100A/s
(5 - 500)A/s
V
m/min
7.8 31.3
35
Welding mode
MIG-MAG manual
ENTER/MEM K
EY
DX K
EY
ENCODER K
- DX
NOB
VISION S
CREEN
.
EY
.
EY
) only on

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DIGITECH vision PULSE Series and is the answer not in the manual?

Table of Contents

Save PDF