External connector/cable

The external connector can be used for the external power supply and external I/O control.
Use the following cable connector (sold separately) for the external cable.
External connector: HR10A-10R-12PB (Hirose Electric) or equivalent product
Cable connector: HR10A-10P-12S (Hirose Electric) or equivalent product
Connector shape:
For using the external I/O control, separate power supply from the unit is required for the external I/O.
The input/output can be used for an external control signal respectively.
The polarity is set to high by default. The high setting is applied while starting up regardless of the [External I/O
Settings] setting
(→P.
When connecting a cable to the external connector, observe the following. Failure to do so may cause incorrect
operation or an accident.
Connect the cable correctly.
Connect or disconnect the cable when the power is off.
Connect the cable to the power supply independently of other devices.
Do not connect the AC adaptor when using the external power supply.
When connecting an external device (input/output), supply the power between the I/O power and I/O GND.
Do not apply the power voltage higher than for the I/O power to the input/output. Do not apply the power voltage
lower than for the I/O GND to the input/output.
Do not connect anything to the pin No.7 (Reserved).
Use an external cable with a cable length of 3 m or less.
Connect an external cable with a ferrite core (sold separately) attached in one place. (Seiwa E04SRS251512 or
equivalent product)
Start the operation of the unit after you confirm that the unit works correctly with all peripheral devices such as a
monitor and power supply connected.
RICOH SC-10 SERIES
Operating Instructions Rev. 4.00
External connector pin assignment:
Pin No.
1
2
3
4
5
6
7
8
9
10
11
12
73).
Signal Name
Power GND
Power input
OUT 0
OUT 1
OUT 2
OUT 3
Reserved
IN 0
IN 1
IN 2
I/O power
IO GND
Specifications
GND for the unit
Power for the unit
12, 24V±10%
Output (Insulated)
Output (Insulated)
Output (Insulated)
Output (Insulated)
Do not connect
Input (Insulated)
Input (Insulated)
Input (Insulated)
I/O power
5V~24V±10%
I/O GND