Overview of operating functions

8
Overview of operating functions
8.1
Functions 'Extinguishing control -> Revision' and
'Extinguishing control -> Test'
Function
Extinguishing control -
> REVISION
Extinguishing control
> TEST
8.1.1

Display test LEDs

8.2

AlgoPilot 'CT11' list of functions 'SECTION'

Building Technologies
Fire Safety
Purpose
Permits activation of sequence of func-
tions without horn, illuminated warning
panel and valves ('active' status visible
at maintenance LEDs E3G080 see
following table chapter 8.1.1) Permits the
disconnection of the path 'Extinguishing
released' via AlgoPilot, e.g. for the test-
ing of third party extinguishing systems
etc.
Normal sequence is possible, however,
without the actuation of the (delayed)
sector valve.
LED
State
H1
Sector valve
H2
Main valve
H3
Alarm horn
H4
Illuminated
warning panel
LEDs H1...H4 are always active
Function list SECTION 'extinguishing'
(based on standard text 'english international')
BLOCKING autom. extinguishing
ENABLING autom. extinguishing
BLOCKING manual exting. release
ENABLING manual exting. release
all DETECTOR zones > OFF
all DETECTOR zones > ON
all DETECTOR zones > TEST
all DETECTOR zones > TEST OFF
all DETECTOR zones > INSTALL. TEST
all DETECTOR zones > INSTALL. TEST OFF
Extinguishing control > REVISION
Extinguishing control > REVISION OFF
Extinguishing control > TEST
Extinguishing control > TEST OFF
Initiate TEST 'horn'
Initiate TEST 'warning panel'
1) Blocking and enabling also possible 'alternating'
Blocking via AlgoPilot 'CT11' and enabling via 'B3Q440' or vice versa
achieved
via AlgoPilot 'CT11'
via switch 'S1' on E3G080
via AlgoPilot 'CT11'
Active
Short circuit
continuously on
rapid flashing
Notes
also possible at operating unit extinguishing 1)
also possible at operating unit extinguishing 1)
concerns all detectors in the extinguishing
SECTION
blocks valves, horn, illuminated warning panel,
acknowledgement
Is also possible on E3G080 by means of
switch 'S1'
blocks sector valve
briefly activates alarm horn (approx. 5 sec.)
briefly activates illuminated warning panel
(approx. 5 sec.)
blocked
Valves
Illuminated warning panel
Alarm horn
Path 'Extinguishing
released'
Valves
Open line
slow flashing
19
009853_b_en_--
01.2013