Motor Current
[1615]
Frequency [%]
[1616]
Torque [Nm]
[1617]
Speed [RPM]
[1618]
Motor Thermal
[1622]
Torque [%]
[1626]
Power Filtered [kW]
[1627]
Power Filtered [hp]
[1630]
DC Link Voltage
[1632]
Brake Energy /s
[1633]
Brake Energy /2 min
[1634]
Heatsink Temp.
[1635]
Inverter Thermal
[1636]
Inv. Nom. Current
[1637]
Inv. Max. Current
[1638]
SL Controller State
[1639]
Control Card Temp.
[1650]
External Reference
[1652]
Feedback [Unit]
[1653]
Digi Pot Reference
[1654]
Feedback 1 [Unit]
[1655]
Feedback 2 [Unit]
[1656]
Feedback 3 [Unit]
[1658]
PID Output [%]
[1660]
Digital Input
[1661]
Terminal 53 Switch Set-
ting
TR200 Programming Guide
Phase current of the motor measured as effective value.
Motor frequency, i.e., the output frequency from the adjustable frequen-
cy drive in percent.
Present motor load as a percentage of the rated motor torque.
Motor speed reference. Actual speed will depend on slip compensation
being used (compensation set in par.1-62
used, actual speed will be the value read in the display minus motor slip.
Thermal load on the motor, calculated by the ETR function. See also pa-
rameter group 1-9* Motor Temperature.
Shows the actual torque produced, in percentage.
Intermediate circuit voltage in the adjustable frequency drive.
Present braking energy transferred to an external brake resistor.
Stated as an instantaneous value.
Braking energy transferred to an external brake resistor. The mean pow-
er is calculated continuously for the most recent 120 seconds.
Present heatsink temperature of the adjustable frequency drive. The cut-
out limit is 203° ± 41°F [95° ± 5 C]; cutting back in occurs at 158° ± 41°F
[70° ± 5 C].
Percentage load of the inverters
Nominal current of the adjustable frequency drive.
Maximum current of the adjustable frequency drive.
State of the event executed by the control
Temperature of the control card.
Sum of the external reference as a percentage, i.e., the sum of analog/
pulse/bus.
Reference value from programmed digital input(s).
View the contribution of the digital potentiometer to the actual reference
Feedback.
View the value of Feedback 1. See also par. 20-0*.
View the value of Feedback 2. See also par. 20-0*.
View the value of Feedback 3. See also par. 20-0*.
Returns the Drive Closed-loop PID controller output value in percent.
Displays the status of the digital inputs. Signal low = 0; Signal high = 1.
Regarding order, see par.16-60
Setting of input terminal 53. Current = 0; Voltage = 1.
Parameter Description
Slip
Compensation). If not
Digital
Input. Bit 0 is at the extreme right.
4-9