Trane TR200 Programming Manual page 262

Hide thumbs Also See for TR200:
Table of Contents

Advertisement

ALARM 30, Motor phase U missing
Motor phase U between the adjustable frequency
drive and the motor is missing.
Turn off the adjustable frequency drive and check
motor phase U.
WARNING
Disconnect power before proceeding.
ALARM 31, Motor phase V missing
Motor phase V between the adjustable frequency
drive and the motor is missing.
Turn off the adjustable frequency drive and check
motor phase V.
WARNING
Disconnect power before proceeding.
ALARM 32, Motor phase W missing
Motor phase W between the adjustable frequency
drive and the motor is missing.
Turn off the adjustable frequency drive and check
motor phase W.
WARNING
Disconnect power before proceeding.
ALARM 33, Inrush fault
Too many power-ups have occurred within a short
time period. Let unit cool to operating temperature.
WARNING/ALARM 34, Fieldbus communica-
tion fault
The serial communication bus on the communication
option card is not working.
WARNING/ALARM 35, Out of frequency rang-
es:
This warning is active if the output frequency has
reached the high limit (set in par. 4-53) or low limit
Process Control, Closed-loop
(set in par. 4-52). In
this warning is displayed.
WARNING/ALARM 36, Mains failure
This warning/alarm is only active if the supply voltage
to the adjustable frequency drive is lost and par.
14-10
Line Failure
is NOT set to OFF. Check the fuses
to the adjustable frequency drive
ALARM 38, Internal fault
It may be necessary to contact your Trane supplier.
Some typical alarm messages:
TR200 Programming Guide
0
Serial port cannot be initialized. Serious hardware
failure
256-258 Power EEPROM data is defect or too old
512
Control board EEPROM data is defect or too old
513
Communication time out reading EEPROM data
514
Communication time out reading EEPROM data
515
Application Orientated Control cannot recognize the
EEPROM data
516
Cannot write to the EEPROM because a write com-
mand is on progress
517
Write command is under timeout
518
Failure in the EEPROM
519
Missing or invalid Barcode data in EEPROM
783
Parameter value outside of min/max limits
1024-
A CAN message that has to be sent, couldn't be sent
1279
1281
Digital Signal Processor flash timeout
1282
Power micro software version mismatch
1283
Power EEPROM data version mismatch
1284
Cannot read Digital Signal Processor software ver-
sion
1299
Option SW in slot A is too old
1300
Option SW in slot B is too old
1302
Option SW in slot C1 is too old
1315
Option SW in slot A is not supported (not allowed)
1316
Option SW in slot B is not supported (not allowed)
1318
Option SW in slot C1 is not supported (not allowed)
1379
Option A did not respond when calculating Platform
Version.
1380
Option B did not respond when calculating Platform
Version.
1536
An exception in the Application Orientated Control
is registered. Debug information written in keypad
1792
DSP watchdog is active. Debugging of power part
data Motor Orientated Control data not transferred
correctly
2049
Power data restarted
2064-207
H081x: option in slot x has restarted
2
2080-208
H082x: option in slot x has issued a power-up wait
8
2096-210
H083x: option in slot x has issued a legal power-up
4
wait
2304
Could not read any data from power EEPROM
2305
Missing SW version from power unit
2314
Missing power unit data from power unit
2315
Missing SW version from power unit
ALARM 39, Heatsink sensor
No feedback from the heatsink temperature sensor.
The signal from the IGBT thermal sensor is not avail-
able on the power card. The problem could be on the
power card, on the gate drive card, or the ribbon ca-
ble between the power card and gate drive card.
WARNING 40, Overload of Digital Output Ter-
(. 1-00)
minal 27
Check the load connected to terminal 27 or remove
short-circuit connection. Check par.5-01
Mode.
WARNING 41, Overload of Digital Output Ter-
minal 29
Check the load connected to terminal 29 or remove
short-circuit connection. Check par.5-02