Input Actuation
(Linear)
D*
α
PT100
= 0.00385
α
PT200
= 0.00385
α
PT500
= 0.00385
α
PT1000
= 0.00385
100 ohm Nickel
120 ohm Nickel
Cu10#
Cu53#
Reference Temperature: 22°C
Reference Humidity:
65% RH +/-15%
* Does not includes reference junction calibration of ±1.0 º C using the standard "ice bath" method of calibration. Factory accuracy can be im-
proved by performing a field calibration. Also does not include any error on the sensor.
** Tolerance for these input types includes that of the external shunt resistors (0.1% tolerance)
*** Use single point compensation to achieve greater accuracy
# not available on the D200
Specification
Pulse Input (optional)
(not available on the D200)
Alarm Outputs (optional)
Digital Input/Output
(optional)
Custom Screens (optional)
(not available for the D200)
Events (optional)
Transmitter Power (optional)
OPC Server (optional)
228
Specification Tables
Range
32 to 356
0 to 180
356 to 3344
180 to 1840
3344 to 4515
1840 to 2490
-328 to 1562
-200 to 850
-328 to 1562
-200 to 850
-328 to 1562
-200 to 850
-328 to 1562
-200 to 850
-76 to 356
-60 to 180
-112 to 500
-80 to 260
-328 to 500
-200 to 260
32 to 302
0 to 150
4 isolated inputs per board, frequency – 1Hz to 25kHz, updated once per sec. Input: Low < 1V, High >4V
to <50V or Volt free input: Low = short circuit, High = open circuit.
Programmable alarm set points (6 per pen) can be configured to activate up to 16 outputs for the D300
and 48 outputs for the D400. Update rate: 200 ms for all alarms. Number/Type:
• 4 or 8 relay contacts SPDT, 3A 240VAC, 3A 24VAC/DC, 0.2A 240VDC (non-inductive, internally
suppressed)
• 8 I/O or 16 I/O - SPNO 1A 24VDC (non-inductive, internally suppressed). 16 I/O not available for
the D200
Activation: Fully programmable internal alarm levels. Assignable to any relay or discrete output.
8 I/O or 16 I/O: all channels may be selected freely as either digital inputs or outputs. The Digital I/O card
also has 4 channels that can be set as pulse inputs (channels 1 to 4). The operating frequency for pulse
inputs on the Digital I/O card is 1kHz max. Input: Low < 1V, High >4.5V to <10V DC (9V to 20V p-p AC) or
Volt free input: Low = short circuit, High = open circuit. 16 I/O not available for the D200
4 relay outputs: all four channels are relay outputs only.
8 relays/ 2 DI card: two outputs can be configured for use as digital inputs: A digital input is provided by a
volt free contact between the normally open (NO) and the common (C) terminals of an output relay. If the
2 Digital inputs are used only 6 relay outputs are available. Closed <500 ohms, Open >300 kohms.
Provides the capability in the recorder to accept custom screen designs from the Screen Designer.
User defined process events are recorded and can be set to cause particular recorder actions. Events can
consist of recording start/stop, digital inputs, alarms, totalising actions, timers, barcode, etc. Once an
event has been caused it can produce a definable set of effects on the recorder which can include, mark
on chart, relay outputs, recording control, Email, Screen change, Print Screen, Totalising actions. Each
event marker can be recorded for analysis using the Trend Software.
D300 has 200mA @ 24VDC ± 3VDC. D400 has 1 Amp @ 24VDC ± 3VDC.
D200 is available with 130mA @ 24VDC TXP as an option on the Comms card.
OPC 3.0 DA & AE compliant. Totalisers and up to 96 pens can be transmitted via OPC server, max poll
rate 1/s.
Accuracy
6.3
4
11.7
1.1
1.1
1.1
1.1
0.9
0.5
5.5***
0.5
Reference Sample Rate: 2Hz (500msec)
Long term stability:
0.2%/year
Options
Temp.
Stability +/-
3.5
0.01%/ °C
2.2
6.5
0.6
0.01%/ °C
0.6
0.01%/ °C
0.6
0.01%/ °C
0.6
0.01%/ °C
0.5
0.01%/ °C
0.3
0.01%/ °C
3.0***
0.01%/ °C
0.3
0.01%/ °C
43-TV-25-35 GLO Iss.4 Dec 06 UK
A5E01001767-04
Input
Impedance