Earth screw
(ground)
Analogue Input
card (option)
Slot B
CJC Sensor
24V TX Power
Supply Output /
RS485 port /
USB Host card
(option)

Analogue Input Card

Each
D400 and up to 6 channels for the
terminal plugs that fit into a PCB header on the rear of the unit. The 2-way CJC sensor
should remain fitted in the central 2-way header.
The SIREC D300 can have two analogue input cards fitted giving up to 16 input channels
(2 x 8 channel cards). The slot positions are A & B, these are identified on the rear panel on
the back of the unit. Either slot can be used, it is recommended that slot A is used if only one
card is fitted.
The SIREC D400 can have up to 6 analogue input cards fitted, up to 48 input channels.
The slot positions A, B, C, D, E or F; these are identified on the rear panel. PC boards are
fitted in order, slot "A" starts from the top.
The
viding up to 6 more channels. This card would be used after using the 3 or 6 channel stand-
ard
To fit this option card into the SIREC D200 recorder you will require an expansion card to
interface to the recorder.
16
Electrical Installation
Wire seal provision
24Vdc TX
Figure 2.5 SIREC D200 Rear panel
has up to 8 input channels for the SIREC D300 and the SIREC
Analogue Input card
can use this card as an additional Analogue Input card fitted in Slot B, pro-
SIREC D200
Analogue Input card which is fitted in Slot A, see .
SIREC D200
20 to 30VDC / 20 to 25VAC Input
Instrument power (option)
RS485
ETHERNET
Analogue Input /
Ethernet connection
card (std) - Slot A
. Connections are made via 2 x 12-way screw
SIREC D200
AC supply
100 - 250 VAC
Alarm Relay or
Digital I/O
Slot G (option)
USB
43-TV-25-35 GLO Iss.4 Dec 06 UK
A5E01001767-04