Section 11: Instrument Care And Maintenance; Cleaning Instructions; Backlights; Operating Temperature - Siemens SIREC D200 Manual

Display recorders
Hide thumbs Also See for SIREC D200:
Table of Contents

Advertisement

Section 11: Instrument Care and Maintenance

The SIREC D200/D300/D400 range of recorders contains no parts serviceable by the
user, except for a fuse on the DC power supply, see
In the event of a recorder failure contact your nearest Service Department (or an author-
ised agent) to arrange for the return of the unit for repair.

Cleaning Instructions

The recorder's touch screen can be temporarily disabled for cleaning, see
on page 116.
Cleaning the unit should be done with a soft lint cloth and warm soapy water or screen
cleaner recommended for use on a PC. Solvents and prolonged exposure to detergents
can cause damage to the front panel. It is recommended that any cloth used for cleaning
is damp but NOT wet, to avoid water collecting in the unit.
For Nema 4X /IP66 rated recorders (option) refer to the Nema 4X standards.

Backlights

1.
2.
3.
4.

Operating Temperature

Operating temperatures are described in
operation at temperatures over 50 °C will accelerate degradation of the display backlight.
If the unit has been moved from a cold environment into a warm one, ensure that the unit
has reached a minimum temperature of 12 °C or is left to stand for 1 hour at room temper-
ature before applying power, to ensure no condensation remains in the unit.
43-TV-25-35 GLO Iss.4 Dec 06 UK
A5E01001767-04
MTTF (Mean Time To Fail) is defined as the time at which 50% of a batch of backlights
remain in excess of half their original brightness i.e. a display has a greater than 50%
chance of being half its original brightness when used at 100% after:
• 55,000 hrs for the SIREC D300. Maximum luminosity 400 cd/m2, (86,000hr if used at 80%).
• 43,000 hrs for the SIREC D400. Maximum luminosity 400 cd/m2, (67,000hr if used at 80%).
• 40,000 hrs for the SIREC D200. Maximum luminosity 450 cd/m2, (62,500hr if used at 80%).
For this recorder the backlight cannot be changed separately so the display has to
be replaced.
Reducing the brightness can significantly improve the life of the backlight.
At extended temperatures these times are reduced.
The backlight is a consumable item, and will NOT last forever.
A maintenance schedule of exchanging backlights should be every 5 years to maintain
the optimal disk clarity.
"Fuses" on page
"Specification Tables" on page
13.