5.4.4
Changing the tolerance of a recognition group is an optional feature. The default tolerance is already suf-
ficient for many applications. It corresponds approximately to the ability of the human eye to differentiate
colors (Delta E = 4.0).
The tolerance is subdivided into the following stages:
The tolerance is accessible in a color management submenu. All colors in one recognition group have the
same tolerance.
colorSENSOR CFO

Tolerance Setting

Sphere
Tolerance
∆E
rel
stage
1
0.5
2
1.0
3
2.0
4
4.0
5
6.0
6
8.0
7
12.0
8
20.0
INT
TEACH
AUTO
CLR
OPT
GATE
1
TEACH
2
HOLD
3
ESC
MULTI
4
TOL
CLASSIFY
5
SPHERE
6
CYLINDER
7
BOX
8
Tolerance space
Cylinder
∆L
∆ab
∆L
1.0
0.5
1.0
2.0
1.0
2.0
4.0
2.0
4.0
8.0
4.0
8.0
12.0
6.0
12.0
16.0
8.0
16.0
24.0
12.0
24.0
40.0
20.0
40.0
Press the TEACH key for longer than 2 sec. to gain access to the (color)
TEACH menu.
Box
∆a
∆b
0.5
0.5
1.0
1.0
2.0
2.0
4.0
4.0
6.0
6.0
8.0
8.0
12.0
12.0
20.0
20.0