Anhang | API Communication with Controller (Version 0.7.1)
A 3.5.3.30 /api/sensor/recognition-profiles/(UUID|current)/autogain
POST
Triggering of automatic level adjustment with following (optional) parameters:
Attribute
level
minimum_sample_
rate
enable_internal_
emitter
Error codes:
LCOL.autogain
LCOL.autogain.invalid_target_level
LCOL.autogain.invalid_sample_rate
LPLC.validation.boolean
A 3.5.3.31 /api/sensor/recognition-profiles/(UUID|current)/white-reference
GET
Read out non-factory white reference
POST
Set white reference (without parameters; current sample is used)
DELETE
Deletion is permissible. (Reset white reference to factory state)
Error codes:
LCOL.white_reference.too_dark
colorSENSOR CFO
Model
Default value
Floating-point
0.8
number
Floating-point
Current sample rate
number
(or 1000)
Floating-point
true
number
Content
Target value for level adjustment
(between 0 and 1)
Desired sample rate
Activate or
switch off internal light source
Page 113